P1110
System Description
This mechanism hydraulically controls cam phases sequentially with the fixed operating angle of the intake valve.
The ECM receives signals such as crankshaft position, camshaft position, engine speed, and engine coolant temperature. Then, the ECM sends ON/OFF pulse duty signals to the camshaft timing control valve depending on driving status. This makes it possible to control the shut/open timing of the intake valve to increase engine torque in low/mid speed range and output in high-speed range.
Consult-II Reference Value In Data Monitor Mode:
ECM Terminals And Reference Value Part 1:
ECM Terminals And Reference Value Part 2:
On Board Diagnosis Logic
Malfunction is detected when
(Malfunction A)
The alignment of the intake valve timing control has been misregistered.
(Malfunction B)
There is a gap between angle of target and phase-control angle degree.
Fail-safe Mode:
FAIL-SAFE MODE
When malfunction A or B is detected, the ECM enters fail-safe mode and the MIL lights up.
Possible Cause
MALFUNCTION A OR B
- Harness or connectors
(Intake valve timing control position sensor circuit is open or shorted.).
- Crankshaft position sensor (REF)
- Crankshaft position sensor (POS)
- Camshaft position sensor (PHASE)
DTC Confirmation Procedure
CAUTION: Always drive at a safe speed.
NOTE:
- If both DTC P1111 (B1), P1136 (B2) or P1140 (B1), P1145 (B2) and P1110 (B1), P1135 (B2) are displayed, perform trouble diagnosis for "DTC P1111 (B1), P1136 (B2) or P1140 (B1), P1145 (B2)" first.
- If "DTC Confirmation Procedure" has been previously conducted, always turn ignition switch "OFF" and wait at least 10 seconds before conducting the next test.
PROCEDURE FOR MALFUNCTION A
With CONSULT-II
1. Turn ignition switch "ON".
2. Select "DATA MONITOR" mode with CONSULT-II.
3. Maintain the following conditions for at least 10 consecutive seconds.
4. Maintain the following conditions for at least 20 consecutive seconds.
5. If 1st trip DTC is detected, go to "P1140, P1145 INTAKE VALVE TIMING CONTROL POSITION SENSOR".
With GST
Follow the procedure "With CONSULT-II" above.
PROCEDURE FOR MALFUNCTION B
With CONSULT-II
1. Turn ignition switch "ON".
2. Select "DATA MONITOR" mode with CONSULT-II.
3. Maintain the following conditions for at least 20 consecutive seconds.
4. If 1st trip DTC is detected, go to "P1140, P1145 INTAKE VALVE TIMING CONTROL POSITION SENSOR".
With GST